Em Thu, 13 Jul 2017 13:50:20 +0100 Kieran Bingham kieran.bingham+renesas@ideasonboard.com escreveu:
On 26/06/17 19:12, Laurent Pinchart wrote:
The sink pointer is used to configure routing inside the VSP, and as such must point to the next VSP entity in the pipeline. The WPF being a pipeline terminal sink, its output route can't be configured. The routing configuration code already handles this correctly without referring to the sink pointer, which thus doesn't need to be set.
Signed-off-by: Laurent Pinchart laurent.pinchart+renesas@ideasonboard.com
Reviewed-by: Kieran Bingham kieran.bingham+renesas@ideasonboard.com
Acked-by: Mauro Carvalho Chehab mchehab@s-opensource.com