On Fri, Oct 25, 2019 at 11:26:22PM +0530, Jagan Teki wrote:
Usage of clocks are varies between different Allwinner DSI controllers. Clocking in A33 would need bus and mod clocks where as A64 would need only bus clock.
To support this kind of clocking structure variants in the same dsi driver,
There's no variance in the clock structure as far as the bus clock is concerned.
explicit handling of common clock would require since the A64 doesn't need to mention the clock-names explicitly in dts since it support only one bus clock.
Also pass clk_id NULL instead "bus" to regmap clock init function since the single clock variants no need to mention clock-names explicitly.
You don't need explicit clock handling. Passing NULL as the argument in regmap_init_mmio_clk will make it use the first clock, which is the bus clock.
Maxime