On Sat, 6 Feb 2021 14:50:20 +0100, Heiko Stuebner wrote:
The panel is able to work when dsi clock is non-continuous, thus the system power consumption can be reduced using such feature.
Add MIPI_DSI_CLOCK_NON_CONTINUOUS to panel's mode_flags.
Also the flag actually becomes necessary after commit c6d94e37bdbb ("drm/bridge/synopsys: dsi: add support for non-continuous HS clock") and without it the panel only emits stripes instead of output.
Applied, thanks!
[1/1] drm/panel: kd35t133: allow using non-continuous dsi clock commit: 54dab3a718f7094532daf7d25cd14121a0e00e34
Best regards,