Hi Magnus,
On Thursday 23 January 2014 18:52:29 Magnus Damm wrote:
On Wed, Jan 22, 2014 at 12:32 AM, Laurent Pinchart wrote:
Add DT bindings for the R-Car DU with support for core resources (memory, IRQ and clocks). Output configuration must still be passed through platform data using OF_DEV_AUXDATA.
Signed-off-by: Laurent Pinchart
laurent.pinchart+renesas@ideasonboard.com
.../devicetree/bindings/video/renesas,du.txt | 49 +++++++ drivers/gpu/drm/rcar-du/rcar_du_drv.c | 161 +++++++++------- 2 files changed, 138 insertions(+), 72 deletions(-) create mode 100644 Documentation/devicetree/bindings/video/renesas,du.txt
Hi Laurent,
Thanks for your patches. I have some minor comments related to r8a7790 vs r8a7791, please see below.
diff --git a/Documentation/devicetree/bindings/video/renesas,du.txt b/Documentation/devicetree/bindings/video/renesas,du.txt new file mode 100644 index 0000000..6bd947c --- /dev/null +++ b/Documentation/devicetree/bindings/video/renesas,du.txt @@ -0,0 +1,49 @@ +* Renesas R-Car Display Unit (DU)
+Required Properties:
- compatible: must be one of the following.
- "renesas,du-r8a7779" for R8A7779 (R-Car H1) compatible DU
- "renesas,du-r8a7790" for R8A7790 (R-Car H2) compatible DU
- "renesas,du-r8a7790" for R8A7791 (R-Car M2) compatible DU
I suppose the last line above should be "renesas,du-r8a7791", right?
- reg: A list of base address and length of each memory resource, one
for
- each entry in the reg-names property.
- reg-names: Name of the memory resources. The DU requires one memory
- resource for the DU core (named "du") and one memory resource for
each
- LVDS encoder (named "lvds.x" with "x" being the LVDS controller
numerical
- index).
- interrupt-parent: phandle of the parent interrupt controller.
- interrupts: Interrupt specifiers for the DU interrupts.
- clocks: A list of phandles + clock-specifier pairs, one for each
entry in
- the clock-names property.
- clock-names: Name of the clocks. This property is model-dependent.
- R8A7779 uses a single functional clock. The clock doesn't need to
be
named.
- R8A7790 and R8A7790 use one functional clock per channel and one
clock
per LVDS encoder. The functional clocks must be named "du.x" with
"x"
being the channel numerical index. The LVDS clocks must be named
"lvds.x" with "x" being the LVDS encoder numerical index.
"R8A7790 and R8A7791"...?
I'll fix both in the next version.