On 2016-06-29 01:17, Meng Yi wrote:
dropped the old "fsl,panel" property, using the of_graph dt binding syntax
Signed-off-by: Meng Yi meng.yi@nxp.com
Changes in V2:
-drop the unit address of port
Documentation/devicetree/bindings/display/fsl,dcu.txt | 9 +++++++-- 1 file changed, 7 insertions(+), 2 deletions(-)
diff --git a/Documentation/devicetree/bindings/display/fsl,dcu.txt b/Documentation/devicetree/bindings/display/fsl,dcu.txt index ae55cde..c96ec1f 100644 --- a/Documentation/devicetree/bindings/display/fsl,dcu.txt +++ b/Documentation/devicetree/bindings/display/fsl,dcu.txt @@ -12,7 +12,7 @@ Required properties:
- clock-names: Should be "dcu" and "pix" See ../clocks/clock-bindings.txt for details.
- big-endian Boolean property, LS1021A DCU registers are big-endian.
-- fsl,panel: The phandle to panel node. +- port Video port for the panel output
Optional properties:
- fsl,tcon: The phandle to the timing controller node.
@@ -24,6 +24,11 @@ dcu: dcu@2ce0000 { clocks = <&platform_clk 0>, <&platform_clk 0>; clock-names = "dcu", "pix"; big-endian;
- fsl,panel = <&panel>; fsl,tcon = <&tcon>;
- port: port {
Port does not need a label here.
dcu_out: endpoint {
remote-endpoint = <&panel_out>;
};
- };
};
Otherwise looks good. However, I would prefer to have this change as part of the corresponding driver change. Can you squash that into the "drm/fsl-dcu: rework codes to support of_graph dt binding for panel" patch?
-- Stefan