On Mon, Jun 20, 2016 at 10:23:38AM +0100, Jon Hunter wrote:
On 17/06/16 17:47, Thierry Reding wrote:
- PGP Signed by an unknown key
On Fri, Jun 17, 2016 at 01:03:46PM +0100, Jon Hunter wrote:
Populate the 'sor-safe' clock for DPAUX devices on Tegra210 that require this clock for operation. Update the compatability string for the DPAUX instance at address 0x545c0000 to be "nvidia,tegra210-dpaux" to ensure that the 'sor-safe' clock is enabled for this device.
Does the second DPAUX need this, too? I have a vague recollection that they were both slightly different.
I have assumed so, but I am checking with the h/w folks on this. Right now the TRM only describes the procedure for configuring the DPAUX pads for i2c6. I am also asking about sharing the DPAUX1 pads with i2c4.
Yes, last time I looked it wasn't documented anywhere with which I2C controller the other DPAUX shared its pads.
It'd be good to get all of that documented in the TRM.
Thierry