Hi Ville,
On Mon, Mar 2, 2020 at 9:34 PM Ville Syrjala ville.syrjala@linux.intel.com wrote:
.mode = { /* The internal pixel clock of the NT35510 is 20 MHz */
.clock = 20000000,
.clock = 23581,
I double checked this with the datasheet NT35510 Application Note V0.07 HYDIS and all documentation is in line with the comment: the internal clock frequency of the dotclock is 20 MHz so this should be set to 20000 (kHz) sorry for putting the three orders of magnitude too big number there :P
This clock isn't used by any drivers because this is a command mode DSI panel with a DSI link clocked from the host. (hs_rate or lp_rate).
The internal formula shows how the actual vrefresh can be calculated for the display in respone to setting of the internal registers, see page 34: https://dflund.se/~triad/NT35510-appnote.pdf
Yours, Linus Walleij