--- Comment #2 from Denis Denisov denji0k@gmail.com --- (In reply to Sergey Kochneff from comment #1)
You should try kernel 4.12. There is some progress with pwm1_enable: now we have not only "1" which is manual control but "0" (full speed) and "2" (this should be FW control, although it doesn’t look so for me: fans are still spinning and pwm1 reads 0 or 122-124 randomly). Still have to use userspace control (mode "1").
I use 4.13.0-041300rc3-generic, but still do not see the differences "pwm1_enable=1" or "pwm1_enable=2". 4.13.0-041300rc3-generic uses the default "pwm1_enable=2". I still need to run the daemon for monitoring the temperature and load of voltage relative fan speed.
$ lsb_release -drc Description: Ubuntu 17.04 Release: 17.04 Codename: zesty
$ uname -rso Linux 4.13.0-041300rc3-generic GNU/Linux